NOISE IS AN ONGOING ISSUE!
 |
In the real world of mobile testing, ambient
noise is not a one-time occurrence—trucks go by,
motorcycles backfire, equipment generators turn on and off,
and subjects cough and sneeze. Because background ambient
noise is a constant part of life, you need assurance that
your testing environment always meets applicable Hearing
Conservation testing standards.

|
|
|
AUTOMATIC, ONGOING
COMPLIANCE
DOCUMENTATION
The BAS-200slm
Bio-Acoustic Simulator/Sound Level Meter solves the background ambient
noise problem with automatic, ongoing compliance. With the BAS-200slm,
your test room is continuously monitored and the CCA-200mini
will accept user response to test signals only when the ambient
noise is within the acceptable range. Your test record will show
the ambient noise for each octave band at test time and document
that the test was performed within acceptable noise levels.
|
|
THE ONLY SEAMLESSLY
INTEGRATED
SOUND
LEVEL METER
The BAS-200slm
Bio-Acoustic Simulator / Sound Level Meter continuously
monitors ambient noise levels in the audiometric testing room,
seamlessly
integrating this data with the CCA-200mini audiometer, to automatically create
a legal record of compliance with OSHA ambient noise regulation
29 CFR 1910.95.
The easy-to-read screen displays,
in real time, ambient noise levels that automatically
turn red when they are too high (View Ambient Noise Level screen). If the ambient
noise is out of compliance, the audiometer will not accept responses and the stimulus is re-presented until the noise returns to acceptable
levels.
|

|
|
|
BUILT-IN FLEXIBILITY
Each test printout physically documents
compliancestep-by-step. But the best part is that the Sound
Level Meter, seamlessly integrated into the CCA-200mini audiometer, allows the
van operator to easily select compliance with OSHA ambient noise
regulations, ANSI requirements, or user-defined maximum permissible
sound levels.
THE BAS-200slm DOES IT ALL!
The BAS-200slm
Bio-Acoustic Simulator/Sound Level Meter is a
dual-function instrument that creates a legal record of the
daily calibration check and of compliance with OSHA ambient
noise regulation 29 CFR 1910.95.
At one time, audiometer operators checked
the ambient noise level at the beginning of each day. Others then
took a stab at
ongoing compliance with an octave band monitor
that would flash a red light if the maximum permissible ambient
noise levels were exceeded.
Unfortunately, this approach was inadequate and didn't offer
anything close to seamless integration. In comparison, the
BAS-200slm
monitors and documents ambient noise throughout each Hearing
Conservation test with
the utmost flexibility, by automatically:
- Meeting ANSI standards for both sound level meters
and octave band filters
- Documenting compliance with OSHA regulations
- Demonstrating in each report that ambient noise
levels were not exceeded
- Storing ambient noise levels with audiogram data,
and
- Supporting OSHA, ANSI, or user-defined maximum
permissible ambient noise levels for Hearing Conservation
|
|
CUSTOM-DESIGNED
FOR A
MOBILE TESTING ENVIRONMENT
The BAS-200slm
Bio-Acoustic Simulator / Sound Level Meter is small
enough to easily mount on the test booth wall, or simply place
on an adjacent tabletop. Multiple BAS-200slm's may be used in group-testing
environments and assigned to monitor ambient noise for particular
audiometric testing stations.
The BAS-200slm was developed specifically
with van operators in mind, because background ambient noise can
be an issue with even the highest-end mobile unit. Now you can get
the ultimate in control and flexibility. Benson Medical
Instruments'
Sound Level Meter continuously monitors ambient noise and seamlessly
integrates this data into the CCA-200mini audiometer so you can easily produce
automatic, on going complianceevery time and everywhere!
|
|
INDUSTRY INNOVATOR WITH
SEAMLESS
SOUND SOLUTIONS
FOR ALL YOUR
HEARING CONSERVATION
NEEDS
Once
considered the new kid on the block, Benson Medical
Instruments has now become the established leader with
the only seamlessly integrated Hearing Conservation testing
system available
today. Maybe this is the reason why the U.S. Military continues
to choose Benson Medical Instruments as its sole developer
and maintainer of occupational audiometry equipment purchased
since 1997. Or maybe its because Benson Medical Instruments
continues to be at the forefront of important audiometry
design breakthroughs.
BENSON MEDICAL INSTRUMENTS WAS THE FIRST
TO:
- Deliver an industrial audiometer that seamlessly
integrates the ability to test, store all data, and output
all reports from one easy-to-use piece of equipment.
- Create an IntelliTesting feature that automatically
scans audiograms for test problems, and
responds with appropriate solutions.
- Incorporate seven standard languages, and now
were
up to 12 (in a stand-alone instrument). The CCA-220 Plus
audiometer can even accommodate 20 additional factory-installed languages,
and
has the ability to hold 32 more, easily installed by you!
- Develop a system for ambient noise level compliance
that meets ANSI standards for sound level meters. Now you can
continuously monitor ambient noise and produce automatic,
ongoing compliance for effective quiet room testing.
- Support new OSHA recordable regulations
and NHCA/CAOHC baseline revision guidelines.
Most importantly, Benson Medical Instruments
was the first to produce a Hearing Conservation testing system that
is so
comprehensive and integrated it is seamless in
its application. Weve brought the art and science of Hearing
Conservation testing into the 21st centurywhere they belong.
|
| |
|